South Korea [229]: data by Dr.J.Wolff, Heppenheim, Germany [158]: data by Dr.Peter Fox, Chichester, UK [39]: data by Ronald R.Holweger, MD, Hays, KS, USA . [371]: data by Dr. Harald Freydell, Medellin, Colombia National Library of Medicine Hanita BunnyLens MF A=118.5 a0=1.22 a1=0.40 a2=0.10 pACD=5.50 sf=1.76 A=118.9 A=119.0 36 [338] Tel: +004 111 1111 111 Website, Universal lens resource for Opthalmologists. [26]: data by K.Ichikawa, MD, Aichi, Japan Lane S, Collins S, Das KK, Maass S, Thatthamla I, Schatz H, Van Noy S, Jain R. Evaluation of intraocular lens mechanical stability. [142]: data by Dr.J.Bauer, Mainz, Germany [240]: data by Dr. Heiko Lgel, Sulzbach, Germany [43]: data by Dr. D. de Ortueta, MD, Recklinghausen, Germany Bookshelf Biotech Vision Eyecryl Plus 600 A=118.0 a0=0.94 a1=0.40 a2=0.10 pACD=5.19 sf=1.42 A=118.4 A=118.5 51 [369] [91]: data by Dr.S.Kohnen, Aachen, Germany [350]: data by Dres. [19]: data by K.Gerstmeyer, MD, Minden, Germany [250]: data by Veronica M. Ferguson, London, UK Rayner C-flex Asph 970 C A=118.0 a0=1.19 a1=0.40 a2=0.10 pACD=5.38 sf=1.63 A=118.8 A=119.2 72 [258],[300],]92] var part3 = "[email protected]"; Ophtec PC 620 Luna - discontinued A=119.0 a0=1.71 a1=0.40 a2=0.10 pACD=5.91 sf=2.13 A=119.6 A=120.0 52 [247] [382]: data by Dr. KIM Joon Hyun, Seoul, South Korea [333]: data by Dr. Alfredo Ferrer, Denia, Spain [224]: data by Dr.F.Bauer, Rosenheim, Germany Secondary surgical interventions include, but are not limited to: lens repositioning, lens replacement, vitreous aspiration or iridectomy for pupillary block, wound leak repair, and retinal detachment repair. If so, do not buy . [206]: data by Dr.J.L.Rodriguez Prats, Alicante, Spain The lens constant is a value without units and is not multiplied or divided by any other variable. [165]: data by Dr.R.Friedrich, Meiningen, Germany [129]: data by J.Chappell MD, Chicago, IL, USA [100]: data by K.Bump, New York, NY, USA When the mouse button is released, from Save and be link. [123]: data by Dr.J.Bosche, Diepholz, Germany Oculentis LS-502-1 A=118.0 a0= -1.014 a1=0.153 a2=0.227 pACD=5.36 sf=1.59 A=118.7 A=119.0 230 [160],[161] [72]: data by Dr.W.Htz, Bad Hersfeld, Germany [319]: data by Dr. Antoni Salvador Playa, Terrassa, Spain [107]: data by Dr.V.Rasch, Potsdam, Germany Jan 2002 [287]: data by Dr. Alexander Tunas, Hamburg, Germany [395]: data by Dr. M. Czubak, Warszawa, Poland [231]: data by Dr.A.Bach, Schwerin, Germany [306]: data by Dr.L.Khaitrine, Reims, France [212]: data by Dr.A.Ilkhani, Singen, Germany [87]: data by Dr.M.-G.Theophil, Eberswalde, Germany [353]: data by Dr. Paul Harton, Dr. Bob Harbin, Rome, GA, USA [254]: data by Dr.U.nsal, Izmir, Turkey [209]: data by Dr.K.Meyer-Hamme, Ludwigsburg, Germany The site is secure. Treatment of negative dysphotopsia with supplementary implantation of a sulcus-fixated intraocular lens. This site needs JavaScript to work properly. [272]: data by Dr.T.Kube / Dr.M.Pache, Bielefeld, Germany [264]: data by Dr. C.Niederdellmann, Friedberg, Germany [226]: data by Dr.T.Neuhann, Mnchen, Germany DISTRA F3000/3013 A=118.2 a0=0.56 a1=0.40 a2=0.10 pACD=4.79 sf=1.01 A=117.7 A=117.8 40 [43] [206]: data by Dr.J.L.Rodriguez Prats, Alicante, Spain [366]: data by Dr. Tomas Prusenowsky, Zlin, Czech Republic Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: one-year follow-up. [373]: data by Dr. Edith Krehn, Bayreuth, Germany Medicontur Bi-Flex 677 (hydrophil acryl) A=118.0 a0= 0.79 a1=0.40 a2=0.10 pACD=4.98 sf=1.19 A=118.0 A=118.0 103 [295],[63] (****): results based on highly myopic patients (mean axial lengths: 29.56 +/- 1.51 mm Physicians considering lens implantation under any of the following circumstances should weigh the potential risk/benefit ratio: Patients in whom the posterior capsule is ruptured, zonules are damaged, or primary posterior capsulotomy is planned. [314]: data by Dr.A.Vasavada et coll., Ahmedabad, India [370]: data by Mr. Azfar W. Chohan, Isle of Man Constants for IOLs characterized by '(Japan)'are based on results for Japanese eyes, which tend to be somewhat longer than Caucasian eyes. [238]: data by Dr.Peter Jungmann, Mannheim, Germany [48]: data by Dr.A.Riel, Kiel, Germany [83]: data by Jack Singer, MD, USA [50]: data by Dr.L.Henke, Gummersbach, Germany [92]: data by Prof.Dr.G.U.Auffarth, Heidelberg, Germany [19]: data by K.Gerstmeyer, MD, Minden, Germany [300]: data by Prof. Dr. Mike Holzer, Heidelberg, Germany Bausch&Lomb Akreos FIT A=118.0 a0=0.78 a1=0.40 a2=0.10 pACD=5.02 sf=1.26 A=118.1 A=118.3 71 [24] 1 review Write a review. [13]: data by Dr.U.Giers, Detmold, Germany Unrivaled Mac notes apps for fuss-free note-taking, 6 Actionable Tips for Improving Your Websites SEO, Copyright 2023 | WordPress Theme by MH Themes. [230]: data by Dr.A.Krmer, Lbeck, Germany [149]: data by Dr.F.Brons, Dortmund, Germany [107]: data by Dr.V.Rasch, Potsdam, Germany [385]: data by Dr. GO Byung Woo, Seoul, South Korea Domilens Nidek NS-60YG Aktis SP y A=118.4 a0=1.61 a1=0.40 a2=0.10 pACD=5.81 sf=2.03 A=119.3 A=119.7 127 [264],[226],[313] [340]: data by Dr. Hanemoto, Mito, Japan [67]: data by Dr.B.Harrisburg, Sidney, Australia [213]: data by Dr.H.Stckl, Neuburg, Germany A Constant: 118.7 (Optical SRK T) ACD constant: 5.61. Aaren Scientific EC-1R PAL A=118.3 a0=1.22 a1=0.40 a2=0.10 pACD=5.37 sf=1.63 A=118.7 A=119.1 55 [319] Alcon, a Novartis Division. [346]: data by Dr. Rudolf Sieben, Aachen, Germany [21]: data by A.Koletzko,MD, Moers, Germany i-Medical Accurate Aspheric A=118.8 a0=1.06 a1=0.40 a2=0.10 pACD=5.23 sf=1.46 A=118.5 A=118.6 30 [74] K.Lucke MD(Bremen, Germany), [387]: data by Dr. BAE Gye Jong, Incheon, South Korea Careers. The manufacturer's published A-constant was almost identical to that obtained in review (118.4 versus 118.38 for the SA30AL and 118.35 for the SA60AT). Oculentis LU-313T A=118.0 a0=0.97 a1=0.40 a2=0.10 pACD=5.18 sf=1.37 A=118.2 A=118.2 162 [394] Zeiss CT LUCIA 201P/PY A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.67 sf=1.93 A=119.3 A=119.9 48 [316] [111]: data by Dr.A.Schweiker, Pforzheim, Germany Below are lens constants for popular IOLs to be used with the Hill-RBF calculator. [204]: data by Y.Kora, Hamamatsu, Japan AMO SI40 NB A=118.0 a0= -0.199 a1=0.276 a2=0.169 pACD=5.19 sf=1.42 A=118.4 A=118.6 1172 [2],[17],[18] [94]: data by Polytech GmbH, Germany [232]: data by Dr.H.J.Gross, Margate, NJ, USA U.Weimantel MD(Karlsruhe, Germany), [374]: data by Dr. J. Joergensen, Dr. R.C. Medicontur Z-Flex 690 A=118.0 a0= 0.237 a1=0.315 a2=0.138 pACD=5.05 sf=1.28 A=118.2 A=118.3 437 [281] [55]: data by W.Hill, MD, USA [308]: data by Dr.B.Mathys, Bruxelles, Belgium [8]: based on data by L.Fry, MD, Garden City, KS, USA This is why we have set HelTecHub as a 501k non-profit which is entirely free. [363]: data by Prof.Dr. [386]: data by Dr. CHO Beom Jin, Incheon, South Korea We are here to respond to your inquiries like choosing the best patient platform, or data storage, or any other solution for your needs. (*****): results based on patients with small mean anterior chamber depth: 2.78 +/- 0.35 mm [157]: data by Dr.G.Scharioth, Recklinghausen, Germany [262]: data by Dr. J.Novak, Pardurbice, Czech Republic [216]: data by Dr.S.Bttmann, Ladenburg, Germany [46]: data by Dr.E.Welzl-Hinterkrner, Zrich, Switzerland Augsburg,Herzberg, Germany Similarly, the Design Factor of Tecnis ZCB00 is 4. [81]: data by Dr.T.Laube, Duesseldorf, Germany HumanOptics Torica-aA(Y) A=118.4 a0=1.18 a1=0.40 a2=0.10 pACD=5.35 sf=1.51 A=118.3 A=118.4 44 [397] Rayner 755 U A=118.0 a0=1.60 a1=0.21 a2=0.11 pACD=5.42 sf=1.67 A=118.8 A=119.0 98 [1] The single-piece acrylic lenses performed well in all regards. Oculentis LS-312Y A=118.0 a0=0.86 a1=0.40 a2=0.10 pACD=5.04 sf=1.25 A=118.1 A=118.3 86 [393] [255]: data by Dr..Kavalcioglu, Istanbul, Turkey (balanced salt solution enriched with bicarbonate, dextrose, and glutathione), CELLUGEL Ophthalmic Viscosurgical Device (OVD), CLEAR CARE Cleaning and Disinfecting Solution, CLEAR CARE Plus Cleaning and Disinfecting Solution with HydraGlyde, (cyclopentolate hydrochloride ophthalmic solution, USP), (cyclopentolate hydrochloride and phenylephrine hydrochloride ophthalmic solution), DAILIES AquaComfort Plus Contact Lenses, DAILIES AquaComfort Plus Multifocal (nelfilcon A) One-Day Contact Lenses, DAILIES AquaComfort Plus Toric Contact Lenses, DAILIES COLORS (nelfilcon A) Soft Contact Lenses, DAILIES TOTAL1 Water Gradient Contact Lenses, DISCOVISC Ophthalmic Viscosurgical Device (OVD), (sodium chondroitin sulfate sodium hyaluronate), EYESCRUB Sterile Eye Makeup Remover and Eyelid Cleansing Pads, FOCUS DAILIES Progressives Contact Lenses, ICAPS Eye Vitamin - AREDS Formula - Softgel, ICAPS Eye Vitamin - AREDS Formula - Coated Tablets, ICAPS Eye Vitamin - Lutein and Zeaxanthin, ICAPS Eye Vitamin & Mineral Supplement - Multivitamin, ISOPTO Atropine (atropine sulfate ophthalmic solution) 1% for topical ophthalmic use, ISPAN Perfluoropropane C3F8 - For use with CONSTELLATION Vision System. IOL nominal Haigis HofferQ Holl.1 SRK/T SRK II n Ref. [287]: data by Dr. Alexander Tunas, Hamburg, Germany AUROLAB FH5600AS (India) A=118.0 a0=0.68 a1=0.40 a2=0.10 pACD=4.92 sf=1.12 A=117.8 A=117.9 99 [288] [152]: data by Dr.Lumbruso, France [34]: data by D.Rotmann, MD, Nordhorn, Germany Biotech Vision Bioacryl 60125 discont. ZEISS CT SPHERIS 203(P) (XL Stabi, XL Stabi Sky) A=118.0 a0=1.05 a1=0.40 a2=0.10 pACD=5.23 sf=1.47 A=118.5 A=118.8 98 [37] (as of Oct 31, 2016): [257]: data by Dr. Klaus Mller, Innsbruck, Austria Ophtec PC420 A=117.2 a0=0.71 a1=0.40 a2=0.10 pACD=4.92 sf=1.14 A=117.9 A=118.1 56 [11] If optimized lens constants are not available, these should be considered as only a starting . [228]: data by Dr.R.v.Horenbeeck, Antwerpen, Belgium Oculentis L-303 A=118.0 a0= 0.962 a1= -0.074 a2=0.161 pACD=5.13 sf=1.36 A=118.3 A=118.4 250 [119],[120],[117],[170],[120],[118],[160] Volume 43 Issue 11 November 2017. Design: Prospective comparative study. Biotech Vision Bioacryl 65 discont. Ocular Implants, Lens Implants, and Devices More. M.Prskavec and M.Wirtitsch, Villach, Austria Ophthalmologe 2002; 99:580-583 ZEISS XL Octo Sky A=117.9 a0=0.99 a1=0.40 a2=0.10 pACD=5.13 sf=1.40 A=118.4 A=118.8 115 [99],[147] [115]: data by Surgivision, USA [137]: data by Dr.L.Banyai, Leonberg, Germany Alcon Laboratories) or the AcrySof UV-filtering IOL (SA60AT: 6.0 mm optic and 13.0 mm overall diameter, Alcon Laboratories); the assignment was random. For relations between optimized IOL constants for different IOL formulas click here. [391]: data by Dr. C. Ameye, Essen, Germany Biotech Vision Eyecryl Plus HSAS600 A=118.0 a0=1.03 a1=0.40 a2=0.10 pACD=5.13 sf=1.37 A=118.3 A=118.5 58 [369] The ratio of the focal length of a digital camera lens to a 35mm still camera lens. J Cataract Refract Surg 2009; 35:663671 Q 2009 ASCRS and ESCRS. Visiontech Medical Optics Liteflex A A=118.2 a0=1.21 a1=0.40 a2=0.10 pACD=5.36 sf=1.57 A=118.6 A=118.7 48 [276] [393]: data by Dres Becker, Cordero, Maruniak. Steinwender, G., MD, et al. [103]: data by Prof.Dr.U.Mester, Sulzbach, Germany Staar KS-3 A=119.0 a0=1.51 a1=0.40 a2=0.10 pACD=5.67 sf=1.91 A=119.1 A=119.8 63 [56] Belquiz Nassaralla, Goiania, Brazil [134]: data by Dr.Chr.Chassain, Montpellier, France [45]: data by Dr.S.Janssen, Belgium Last Revision: Oct 31, 2016 WH, [49],[223],[224],[84],[33],[245],[122],[246],[271],[272],[286],[350], [2],[5],[10],[16],[18],[32],[66],[67],[46],[85],[90],[101],[25],[171],[252],[269], [55],[90],[5],[112],[113],[127],[98],[101],[129],[130],[25],[156],[159],[171],[172],[225],[235],[244],[250],[260],[121],[279],[278],[318],[324],[331],[339],[344],[370], [109],[139],[140],[19],[103],[104],[72],[98],[232],[234],[239], [63],[84],[109],[110],[111],[133],[158],[217], [143],[144],[145],[132],[163],[164],[165],[166],[167],[168],[18],[169],[241],[242],[265],[303],[322], [119],[120],[117],[170],[120],[118],[160], [277],[283],[94],[282],[287],[317],[81],[346], ZEISS CT SPHERIS 203(P) (XL Stabi, XL Stabi Sky), [148],[151],[152],[153],[154],[155],[205],[305],[306],[307],[308],[309],[310], ZEISS CT ASPHINA 409M (Acri.Smart 46LC), [378],[379],[380],[381],[382],[383],[384],[385],[386],[387], For relations between optimized IOL constants for different IOL formulas click, For relations between IOL constants for optical and acoustical biometry click, The following table may be downloaded and fed directly into the. In verbal descriptions, IOL optic centration was assessed to be within 0.4 mm of perfect in 75 (95%) of 79 cases. The crop factor is used by experienced photographers, who want to know the field of view of a lens on a digital camera as compared to a lens on an analog 35mm camera, which they have been using for years. [44]: data by E.Hurst, MD, USA SA60AT SA60WF SN60WF CCA0T0 CNA0T0 CZ70BD ACU0T0 SY60WF Packaged service / item; no separate payment made V2630 Anterior chamber intraocular lens MTA3U0 MTA4U0 MTA5U0 Packaged service / item; no separate payment made V2787 Astigmatism-correcting function of intraocular lens (covered conventional IOL component may be reported as V2632) SA6AT3 . An official website of the United States government. Omni LBHY32UVASP A=119.0 a0=1.70 a1=0.40 a2=0.10 pACD=5.88 sf=2.14 A=119.6 A=120.0 49 [349] [2]: results based on data by Biotech Vision Eyecryl-SERT PLHF2 A=118.5 a0=1.03 a1=0.40 a2=0.10 pACD=5.25 sf=1.46 A=118.4 A=118.6 55 [369] [380]: data by Dr. LEE Junhun, Daegu, South Korea [381]: data by Dr. KIM Joung Mok, Seoul, South Korea Alcon, a Novartis Division. Moss Vision Optiflex MO/F-013 A=118.0 a0=0.71 a1=0.40 a2=0.10 pACD=4.85 sf=1.10 A=117.9 A=118.0 50 [369] [37]: data by F.C.Nickel, MD, Peine, Germany The IOLs.eu/IOLs.gr is not responsible for inaccurate Data or wrongful claims. We use cookies to ensure that we give you the best experience on our website. A critical analysis of 1000 consecutive cases. [7]: based on data by G.Gerten, MD, Cologne, Germany The AcrySof IOL (model SA60AT) is an ultraviolet-absorbing acrylic foldable single-piece lens. (+): Identical IOL with same constants available from other source, click for details. Domilens Nidek Nex-Acri N4-18YG AKTIS AA A=118.4 a0=1.34 a1=0.40 a2=0.10 pACD=5.51 sf=1.73 A=118.9 A=119.2 57 [257] HHS Vulnerability Disclosure, Help [160]: data by Dr.R.Lehmann, Mnchengladbach, Germany (*): A-const taken from: Mohr A, Hengerer F, Eckardt C: Retropupillare Fixation der Irisklauenlinse bei Aphakie. [383]: data by Dr. KIM Jun Heon, Seoul, South Korea Curamed SA700 A=118.8 a0=1.31 a1=0.40 a2=0.10 pACD=5.52 sf=1.75 A=118.8 A=118.9 114 [25] [144]: data by Dr.W.Schindler, Eichsttt, Germany [295]: data by Dr. M. Meyner, Schramberg, Germany Epub 2015 May 7. C.Wehner MD(Bremervrde, Germany), C.Grenauer-Kloevekorn, Halle, Germany If the item is subject to FDA regulation, seller must verify your status as an authorized purchaser of this item before shipping of the item. Alcon ReSTOR SN6AD1/3 (India) A=119.1 a0=1.35 a1=0.40 a2=0.10 pACD=5.57 sf=1.80 A=119.0 A=119.3 66 [314] i-Medical i-Soft A=118.8 a0=1.24 a1=0.40 a2=0.10 pACD=5.44 sf=1.64 A=118.6 A=119.0 107 [128] [258]: data by Dr. Mark Fajgenbaum and Mr.C.Liu, Sussex, UK [14]: data by P.Ursin, Nordhausen, Germany Canon AQ-310AI (Japan) A=119.5 a0=2.17 a1=0.40 a2=0.10 pACD=6.32 sf=2.52 A=120.1 A=120.7 68 [26] [359]: data by Dr. H. Siatiri, Tehran We welcome your input for improving our users Experience. [334]: data by Dr. Humberto Carreras, Las Palmas, Spain [18]: data by P.Hoffmann, MD, Castrop-Rauxel, Germany [289]: data by HSK Wiesbaden, Germany All Trademarks referred to are the property of their respective owners. [323]: data by Dr. Katrin Hermes, Oranienburg, Germany IT TAKES SEEING THINGS DIFFERENTLY TO GO BEYOND. [110]: data by Dr.H.Wenkel, Coburg, Germany Morcher TYPE 92S A=119.7 a0=1.40 a1=0.40 a2=0.10 pACD=5.60 sf=1.84 A=119.1 A=119.6 71 ]362] [120]: data by Dr.L.Tschernjakov, Berlin, Germany Curamed ASPHERICx HP60CA (+) A=118.4 a0=1.10 a1=0.40 a2=0.10 pACD=5.28 sf=1.51 A=118.5 A=118.8 38 [25] // -->, Clareon CNWTT0 PanOptix / CNWTTx PanOptix Toric, PanOptix TFNT00 Trifocal / TFNTxx Trifocal Toric, Tecnis 3-piece Multifocal ZMA00 +4.00 add, CT LUCIA 602 (previously Aaron Scientific EC-3 PAL). Physiol PodEye A=118.9 a0=1.70 a1=0.40 a2=0.10 pACD=5.85 sf=2.06 A=119.4 A=119.8 71 [351] Oculentis L-400 (45C) A=118.0 a0= 0.202 a1=0.075 a2=0.179 pACD=5.19 sf=1.44 A=118.4 A=118.8 209 [36],[51],[86] [95]; data by Dr.R.Wertheimer,Mnchen, Germany ARGONOPTICS TRICE A=118.0 a0=1.13 a1=0.40 a2=0.10 pACD=5.28 sf=1.49 A=118.5 A=118.7 60 [162] [338]: data by Dr. Ruth Lapid-Gortzak, Driebergen, The Netherlands (****): results based on highly myopic patients (mean axial lengths: 29.56 +/- 1.51 mm